boxing equipment

Before ordering a commercial MMA cage, ask the supplier to confirm the usable training area, total installed footprint, installation method and full supply list on a dimensioned drawing. Then compare quotations against that same drawing. A headline cage size and a product photograph are not enough to confirm that the equipment fits your room or that two offers include the same components.

This checklist is for gym owners, equipment distributors and contractors planning an MMA training space. For a sanctioned event, obtain the organizer’s and relevant governing body’s equipment requirements before selecting a model. A product described as “professional” should not be treated as proof of approval for a particular competition.

By EVB | Updated September 14, 2026

Choose the Cage Type Before Comparing Sizes

Start with the training plan. Decide whether the space must support enclosed MMA training, wall-work drills, coaching sessions or a specified event. Also decide whether the equipment will remain installed or must be dismantled between uses.

EVB’s current product pages provide three useful starting points:

ConfigurationBest starting pointVerifiable information on the current EVB pageWhat still needs project confirmation
Floor MMA cageEVB Floor MMA CageOctagonal floor cage; listed sizes: 4 m, 5 m and 6 m; ground installation without a raised platform; modular bolt connectionWhether the listed size is internal or external, side-to-side or corner-to-corner; complete outer footprint; floor interface; door position; included floor layers
Raised-platform cage proposalEVB Professional MMA CageOctagonal cage; listed sizes: 5 × 5 m, 6 × 6 m, 7.3 × 7.3 m, 7.6 × 7.6 m and 9.1 × 9.1 m; page lists a chain-link fence, padded system, floor system and lockable access doorWhether the quoted configuration includes a platform; measurement convention; platform height; steps; complete footprint; exact door and floor details for the proposed model
Cage wall panelsEVB MMA Cage Wall PanelsModular wall-panel system for dividing or configuring training areas; the page describes a steel structure and padded systemPanel quantity and dimensions, support and mounting method, corners, entrances, floor interface and whether the proposed layout is freestanding or fixed

These public page dimensions are reproduced only as listed. The pages do not clearly state whether they are internal or external measurements, or whether octagonal dimensions run between opposite sides or opposite corners. Do not convert them into room dimensions or treat them as final project specifications. Ask EVB to mark the measurement endpoints on the model-specific drawing.

A wall-panel layout should not be assumed to provide the enclosure, supports, entrance or floor system of a complete cage. Likewise, a professional cage page is not confirmation that a platform, steps or event-specific requirements are included in a quotation.

Plan Internal Training Area and External Footprint Separately

For an octagonal cage, ask the supplier to label all of the following on one drawing:

MMA cage planning illustration showing internal dimensions, the outer footprint and access review

Planning illustration only. Not to scale, not an installation drawing and not a representation of a specific EVB model.

Do not use the internal cage dimension as the required room size. The supplier and installer should review the complete arrangement. Have site-specific structural, building and circulation requirements checked by a qualified local professional.

Also check the delivery route before ordering. Packed frame sections, panels and platform components must pass through the available doors, corridors and lifts. Ask for packed component dimensions rather than assuming that a cage delivered in sections will fit every access route.

What Should an MMA Cage Quote Include?

Send every supplier the same brief and ask for an itemized quotation tied to a drawing revision. Each line should be marked included, optional, excluded or to be confirmed.

“Complete cage” is not a substitute for an itemized supply list. If flooring, freight, unloading, local installation or import charges are excluded, record those costs separately. Leave unresolved costs blank or mark them “to be confirmed”; do not enter zero.

Use the free EVB MMA Cage Procurement Workbook to prepare a project brief, compare quotations side by side and record the documents required before a deposit. It is a blank working document, not a price list.

Keep the production schedule separate from freight, customs clearance and local installation. Ask which milestones depend on drawing approval, artwork approval or payment. A production estimate alone is not an opening-date commitment.

Assign Installation Responsibilities Before Production

Provide a measured floor plan and photographs of the installation area. Include the floor construction if known, any restrictions on drilling, loading access and the route from the delivery point to the room.

Agree in writing who is responsible for:

ResponsibilityConfirmation required
SupplierModel-specific drawing, bill of materials, assembly instructions, connection and padding details, packed dimensions and identified replacement parts
Buyer or facility teamAccurate room information, access restrictions, intended use, destination and local site requirements
InstallerLabor, tools, assembly sequence, floor preparation and completion checks required by the manufacturer’s instructions
Qualified local reviewerAny site-specific structural, substrate, anchoring, building or circulation requirements
Logistics providerFreight scope, customs responsibility, unloading and final movement into the building

Where anchoring is required, confirm who specifies and supplies the anchors and who verifies the substrate. Do not choose anchors from a photograph or apply a generic fixing method to an unknown floor.

If the cage will be dismantled regularly, request the model-specific dismantling procedure, packed dimensions, storage requirements, labor and tools. Do not rely on an installation time quoted for a different configuration.

Check Maintenance and Replacement Parts

Before ordering, ask for model-specific documents and close-up images of parts that will need inspection or replacement. A finished-cage photograph is not enough.

Ask how to report damage, identify the correct spare part and obtain the manufacturer’s advice on whether the equipment should remain out of use. If a document or replacement arrangement is unavailable, record that gap in the comparison workbook. This checklist does not replace a safety inspection or the manufacturer’s instructions.

Confirm Evidence Before Shipment

Agree before production what evidence can be supplied for the actual order. A useful request can include an overview of the assembled configuration where available, close-up photographs of connections, door hardware and padding, confirmation of approved artwork, and a packing list identifying the components.

If measurements, a video call or an independent inspection are required, put that requirement in the order documents. On arrival, reconcile the shipment with the packing list and record visible transport damage before assembly. Have the installer complete the checks required by the manufacturer’s instructions.

Send a Complete MMA Cage RFQ

For a project-specific quotation, submit the following through EVB’s Get a Quote page:

Ask for a model-specific drawing, an itemized supply list and a quotation that identifies inclusions, exclusions and delivery terms. Prices, production timing and installation requirements must be confirmed for the actual project.

MMA Cage Buying FAQs

Is a floor MMA cage the same as a raised-platform cage?

No. A floor cage is installed at ground level without a raised platform. A platform changes the total height, access, steps, floor system, footprint and installation scope. Confirm each item on the proposed model drawing and quotation.

What do EVB’s listed MMA cage sizes measure?

The current floor-cage page lists 4 m, 5 m and 6 m, while the professional-cage page lists 5 × 5 m, 6 × 6 m, 7.3 × 7.3 m, 7.6 × 7.6 m and 9.1 × 9.1 m. Those pages do not clearly define internal versus external measurement or side-to-side versus corner-to-corner measurement. Request a dimensioned drawing with marked endpoints before using a listed size for room planning.

Can wall panels replace a complete MMA cage?

Not automatically. Wall panels can suit wall-work drills or a training-area boundary, but the quoted layout must identify its supports, mounting, padding, corners, entrances and floor interface. Do not assume that a panel package includes the enclosure and floor system of a complete cage.

How much room should I allow around an MMA cage?

There is no single clearance figure in this checklist. Start with the actual outer footprint, door and access arrangement. Then have the supplier, installer and facility team review circulation and applicable local requirements. Internal training dimensions alone do not establish the required room size.

What should I confirm before paying a deposit?

Confirm the dimensioned drawing and revision, itemized component list, customization approvals, payment and delivery terms, installation responsibilities, evidence required before shipment, and written warranty and replacement-part arrangements. Keep unresolved items visible in the order documents rather than in separate chat messages.

Is a professional MMA cage automatically approved for an event?

No. Obtain the organizer’s and relevant governing body’s current requirements for the specific event. Product naming, photographs or a previous installation do not prove approval for another competition or venue.